{"id":1725,"date":"2019-07-13T21:27:15","date_gmt":"2019-07-13T21:27:15","guid":{"rendered":"http:\/\/pmarchitecture.pl\/?page_id=1725"},"modified":"2019-07-13T21:27:15","modified_gmt":"2019-07-13T21:27:15","slug":"equipment-and-lighting-loads","status":"publish","type":"page","link":"https:\/\/pmarchitecture.pl\/?page_id=1725&lang=en","title":{"rendered":"Equipment and Lighting Loads"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Lighting, HVAC equipment, water heaters, and appliances all consume energy in the form of either electricity or fuel. All of these things are important to understand and optimize for high performance building design, and are important inputs for whole building energy analysis simulation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The equipment, lighting, and plug loads described below are determined by the building\u2019s intended use, its occupancy, and its scheduling. In short: its&nbsp;<a href=\"\/\/sustainabilityworkshop.autodesk.com\/buildings\/building-program-and-schedule\" target=\"_blank\" rel=\"noreferrer noopener\">program<\/a>.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Lighting Loads<\/h3>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"alignright\"><img fetchpriority=\"high\" decoding=\"async\" width=\"400\" height=\"266\" src=\"http:\/\/pmarchitecture.pl\/wp-content\/uploads\/2019\/07\/lighting_relativepower_1.jpg\" alt=\"\" class=\"wp-image-1726\" srcset=\"https:\/\/pmarchitecture.pl\/wp-content\/uploads\/2019\/07\/lighting_relativepower_1.jpg 400w, https:\/\/pmarchitecture.pl\/wp-content\/uploads\/2019\/07\/lighting_relativepower_1-300x200.jpg 300w\" sizes=\"(max-width: 400px) 100vw, 400px\" \/><figcaption> <em>Incandescent and compact fluorescent bulbs emit similar output of visible light, but the incandescent emits far more heat (infrared light), causing higher lighting loads and cooling loads.\u00a0(From\u00a0<a rel=\"noreferrer noopener\" href=\"http:\/\/www.pge.com\/pec\/\" target=\"_blank\">Pacific Energy Center<\/a>)<\/em> <\/figcaption><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Lighting loads are the energy used to power electric lights; they make up nearly a third of US commercial building energy use, but for residential buildings they are generally only 10 &#8211; 15%. &nbsp;Lighting loads in a building are often referred to in terms of a \u201cLighting Power Density\u201d that is measured in watts per square foot or square meter.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When deciding which lighting products to use, look at the efficiency (or luminous efficacy) of the products. More efficient light sources and fixtures not only reduce lighting loads, but also reduce cooling loads for the same visible brightness.<\/p>\n\n\n\n<p class=\"has-background has-white-background-color wp-block-paragraph\"><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Plug loads<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Plug loads are the electricity used for other equipment, like computers and appliances; they make up 20 &#8211; 30% of energy loads in US commercial buildings, and 15 &#8211; 20% of home energy, though these numbers are growing as electronics become more pervasive.&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Plug loads are sometimes included in \u201cEquipment Power Density\u201d (EPD) and sometimes they are separated. When doing building analysis, it\u2019s important to know which value you\u2019re inputting.<\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td><strong>Equipment<\/strong><\/td><td><strong>Rated Power (watts)<\/strong><\/td><\/tr><tr><td>Desktop computer<\/td><td>120<\/td><\/tr><tr><td>Notebook computer<\/td><td>45<\/td><\/tr><tr><td>17\u201d LCD Display<\/td><td>75<\/td><\/tr><tr><td>Desktop laser printer<\/td><td>120<\/td><\/tr><tr><td>Office laser printer<\/td><td>250<\/td><\/tr><tr><td>Office copier<\/td><td>750<\/td><\/tr><tr><td>Refrigerator<\/td><td>750<\/td><\/tr><tr><td>Dishwasher<\/td><td>1,200<\/td><\/tr><tr><td>Television<\/td><td>100<\/td><\/tr><tr><td>Commercial refrigerator<\/td><td>1,000<\/td><\/tr><tr><td>Commercial fryer<\/td><td>10,000<\/td><\/tr><tr><td>Clothes washer<\/td><td>350<\/td><\/tr><tr><td>Clothes dryer<\/td><td>2,000<\/td><\/tr><tr><td><em>Plug loads for specific items&nbsp;<\/em><em>(Source: USGBC and&nbsp;<a href=\"http:\/\/www.energystar.gov\/index.cfm?c=products.pr_find_es_products\" target=\"_blank\" rel=\"noreferrer noopener\">EnergyStar<\/a>)<\/em><\/td><\/tr><\/tbody><\/table>\n\n\n\n<h3 class=\"wp-block-heading\">Equipment Loads<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">Equipment, like HVAC systems and water heaters, is the other main internal load. This is typically separated from plug loads and is given in terms of an \u201cEquipment Power Density,\u201d which is measured in watts per square foot or square meter .<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">When deciding which equipment to use, look at third-party quantitative reviews, or read the maximum power use listed on product specification sheets (average power use data is usually not available because it can vary greatly by usage.)&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Example Internal Loads for Different Space Types<\/strong><\/em><\/p>\n\n\n\n<table class=\"wp-block-table is-style-stripes\"><tbody><tr><td>&nbsp;<\/td><td><strong>Lighting Power Density&nbsp;<\/strong><\/td><td><strong>Equipment Power Density&nbsp;<\/strong><\/td><td><strong>Plug Loads (Peak)&nbsp;<\/strong><\/td><td><strong>Occupancy&nbsp;<\/strong><\/td><\/tr><tr><td>&nbsp;<\/td><td><strong>W\/m<sup>2<\/sup><\/strong><\/td><td><strong>W\/ft<sup>2<\/sup><\/strong><\/td><td><strong>W\/m2<\/strong><\/td><td><strong>W\/ft<sup>2<\/sup><\/strong><\/td><td><strong>W\/m<sup>2<\/sup><\/strong><\/td><td><strong>W\/ft<sup>2<\/sup><\/strong><\/td><td><strong>People\/100m<sup>2<\/sup><\/strong><\/td><\/tr><tr><td><strong>Assembly<\/strong><\/td><td>17<\/td><td>1.6<\/td><td>10<\/td><td>0.9<\/td><td>2.2<\/td><td>0.2<\/td><td>75<\/td><\/tr><tr><td><strong>Classroom<\/strong><\/td><td>13<\/td><td>1.2<\/td><td>11<\/td><td>1.0<\/td><td>10<\/td><td>0.9<\/td><td>25-35<\/td><\/tr><tr><td><strong>Food Service<\/strong><\/td><td>15<\/td><td>1.4<\/td><td>9<\/td><td>0.8<\/td><td>13<\/td><td>1.2<\/td><td>15-40<\/td><\/tr><tr><td><strong>Office<\/strong><\/td><td>11-30<\/td><td>1.0-2.8<\/td><td>14<\/td><td>1.3<\/td><td>27<\/td><td>2.5<\/td><td>3.5-5<\/td><\/tr><tr><td><strong>Retail<\/strong><\/td><td>16<\/td><td>1.5<\/td><td>10<\/td><td>0.9<\/td><td>4.5<\/td><td>0.4<\/td><td>10-20<\/td><\/tr><tr><td><strong>Residential (single family)<\/strong><\/td><td>5<\/td><td>0.5<\/td><td>5<\/td><td>0.5<\/td><td>NA<\/td><td>NA<\/td><td>1<\/td><\/tr><tr><td><strong>Residential (multi family)<\/strong><\/td><td>8<\/td><td>0.7<\/td><td>11<\/td><td>1.0<\/td><td>NA<\/td><td>NA<\/td><td>2.5<\/td><\/tr><tr><td><strong>Warehouse<\/strong><\/td><td>9<\/td><td>0.8<\/td><td>5<\/td><td>0.5<\/td><td>2.2<\/td><td>0.2<\/td><td>1.5<\/td><\/tr><\/tbody><\/table>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>Note that this information can vary greatly based on the design and use of the space. Use more precise and specific estimates when available.<\/strong>\u00a0(Sources: United States Department of Energy (1 and 2),\u00a0and\u00a0<a rel=\"noreferrer noopener\" href=\"http:\/\/www.amazon.com\/Mechanical-Electrical-Equipment-Buildings-Grondzik\/dp\/0470195657\" target=\"_blank\">Mechanical and Electrical Equipment for Buildings<\/a>\u00a0by Grondzik et al.)<\/em><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Links and References<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><a rel=\"noreferrer noopener\" href=\"http:\/\/www.energystar.gov\/index.cfm?c=products.pr_find_es_products\" target=\"_blank\">Energy Star Database<\/a>A database of more energy efficient appliances and equipment. Includes really helpful reference information about basic metrics and efficiency standards.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lighting, HVAC equipment, water heaters, and appliances all consume energy in the form of either electricity or fuel. All of these things are important to understand and optimize for high performance building design, and are important inputs for whole building &hellip; <a href=\"https:\/\/pmarchitecture.pl\/?page_id=1725&#038;lang=en\">Continued<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":1715,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-fullwidth.php","meta":{"footnotes":""},"class_list":["post-1725","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/pages\/1725","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=1725"}],"version-history":[{"count":1,"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/pages\/1725\/revisions"}],"predecessor-version":[{"id":1727,"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/pages\/1725\/revisions\/1727"}],"up":[{"embeddable":true,"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=\/wp\/v2\/pages\/1715"}],"wp:attachment":[{"href":"https:\/\/pmarchitecture.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=1725"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}